- EBU QC Id
- 0150W
- Name
- Body Partition Duration
- Status
- published
- Category
- absolute
- Lead editor
- Frans De Jong
- Aliases
- Tags
- MXF MXF-only
Version | Status | Edition date | Saved by | Note |
---|
- Definition
- Used in Checks, the system shall measure the duration of the body partition(s) and check if it matches the expected one specified in the input. Optionally the system may report the body partition duration.
Used in Reports, the system shall measure the duration of the body partition(s) and report it. - References
-
-
SMPTE ST 377-1:2011
Remark: MXF
-
SMPTE RDD 9:2013
Remark: Sony MPEG Long GOP in MXF
-
- Examples
-
-
Input: "Body Partition Duration Expected" = 300 frames
Input: "Body Partition To Check" = all
Output: "Check Result" = false
Output: "Body Partition Duration Segment" = 300 frames from 10:00:00:00 to 10:00:12:00
Output: "Body Partition Duration Segment" = 300 frames from 10:00:12:00 to 10:00:24:00
Output: "Body Partition Duration Segment" = 301 frames from 10:00:24:00 to 10:00:36:01Remark: Used as a Checks The example shows how the locator provides information on which Body Partitions do (not) have the expected Duration.
-
Input: None
Output: "Body Partition Duration Segment" = 45001 frames from 10:00:00:00 to 10:30:00:01
Remark: Used as a Reports In this example there is a single Body Partition.
-
Name | Default value | Description | Data model name | Unit | Locator |
---|
Name | Alias | Description | Data model name | Unit | Locator |
---|
Title | Version | Download |
---|
- Remarks
- This Test is a measurement Test only.
Title | Author | Last update |
---|