- EBU QC Id
- 0084B
- Name
- Audio Peaks (TP)
- Status
- published
- Category
- absolute
- Lead editor
- Roman Meszmer
- Aliases
- true peak TP
- Tags
- audio
Version | Status | Edition date | Saved by | Note |
---|
- Definition
- System shall check True Peak levels against a user-defined value.
- References
-
-
[http://tech.ebu.ch/docs/r/r128.pdf EBU R 128]
-
[http://tech.ebu.ch/docs/tech/tech3343.pdf EBU Tech 3343]
-
[http://tech.ebu.ch/docs/tech/tech3344.pdf EBU Tech 3344]
-
ITU-R BS.1770-3
-
ATSC A/85
-
- Examples
-
-
00:00:40:20 Audio peak detected, -10dBTP.
-
00:00:56:15 Audio peak detected, -13dBTP.
-
Name | Description |
---|
Name | Description |
---|
Title | Version | Download |
---|
- Remarks
-
The max TP level for linear audio in production is -1dBTP (see EBU R 128 and EBU Tech 3343).
Where bitrate compression is used, -3 dBTP may apply (see EBU Tech 3344).
Note that (Q)PPM and true peak are different measurements.
With the introduction of loudness measurement (see 0010B), PPM measurements are being replaced with Loudness and TP measurements.
The (Q)PPM test item is 0085B.
Title | Author | Last update |
---|