- EBU QC Id
- 0026W
- Name
- Timecode
- Status
- published
- Category
- absolute
- Lead editor
- Friedrich Gierlinger
- Aliases
- tc
- Tags
- MXF timecode MXF-only
Version | Status | Edition date | Saved by | Note |
---|
- Description
- In MXF timecode can be located in the Material Package, Source Package and System Item.
Discontinuities are not allowed in the Material Package timecode for OP1a, but for the Source Package multiple timecode component sets are allowed.
For frame-based wrapping, each System Item can have its own timecode. In that case, the first System Item timecode found shall be the "Start Timecode". - Definition
- Used in Checks, the system shall read out the available start timecode(s) indicated in the wrapper metadata and check against the user input. For the Source Package and System Item start-timecode, the system shall also report where discontinuities exist. Optionally the system may report the read out start timecode(s) indicated in the wrapper metadata.
Used in Reports, the system shall read out the available start timecode(s) indicated in the wrapper metadata. For the Source Package and System Item start timecode, the system shall also report if discontinuities exist. - References
-
-
Remark: MXF Timecode Implementation
-
Remark: Mapping SDTI-CP data in the MXF Generic Container
-
Remark: MXF (revision 2009 and newer)
-
Remark: MXF profile used in e.g. Germany
-
Remark: MXF profile used in e.g. France
-
- Examples
-
-
Input: "Material Package Start Timecode Expected" = 10:00:00;00
Input: "Source Package Start Timecode Expected" = 11:00:00;00
Input: "System Item Start Timecode Expected" = 12:00:00;00
Output: "Check Result" = false
Output: "Timecode Discontinuity Detected" = at video frame 91200 (WrapperLocation=System Item)
Output: "Timecode Discontinuity Detected" = at video frame 96200 (WrapperLocation=System Item)
Output: "Material Package Start Timecode" = 10:00:00;00
Output: "Source Package Start Timecodet" = 10:00:00;00
Output: "System Item Start Timecode" = 10:00:00;00Remark: Used as a Check.
-
Input: none
Output: "Material Package Start Timecode" = 10:00:00;00
Output: "Source Package Start Timecode" = 10:00:00;00
Output: "System Item Start Timecode " = 10:00:00;00
Output: "Timecode Discontinuity Detected" = at video frame 96200 (WrapperLocation=Source Package)
Output: "Timecode Discontinuity Detected" = from frame 96200 to frame 96205 (WrapperLocation=System Item)Remark: Used as a Report.
-
Name | Default value | Description | Data model name | Unit | Locator |
---|
Name | Alias | Description | Data model name | Unit | Locator |
---|
Title | Version | Download |
---|
- Remarks
-
Since MXF version 1.3 it is clearly defined how timecode shall be implemented in case of existing Origin/PreCharge.
Unfortunately it cannot be measured if the timecode is written correctly because of the possibility to write any timecode in the different packages. So this Test is a readout only.
Title | Author | Last update |
---|