0014B - Audio Test Tones
v2.0
published
0014B
v2.0
TEST TONES
Standard Test Tones
EBU Tech 3304 BLITS, GLITS
Duration, Search Area, Freq.
Tone Type, Channel Number
https://qc.ebu.io/items/0014B/versions/2-0-0/
Check
Report
Summary
- EBU QC Id
- 0014B
- Name
- Audio Test Tones
- Status
- published
- Category
- absolute
- Lead editor
- Eric Carson
- Aliases
- monotone audio detection line-up tone
- Tags
- audio
Versions
Version | Status | Edition date | Saved by | Note |
---|
Details
- Definition
- System shall detect if standard test tones are present in the programme. This test item can be used in conjunction with EBU QC Test Item 0052B.
In the frequency domain, the system will seek out single tone audio, either at a specific frequence (such as 440 Hz) or at any frequency. The system will also seek out known test patterns, including "left ident" test tone, in which one channel periodically drops to silence.
Optionally, aditional test patterns (such as GLITS and BLITS) may be detected. - References
-
-
[https://tech.ebu.ch/docs/tech/tech3304.pdf EBU Tech 3304]
Remark: BLITS (BSkyB)
-
[https://tech.ebu.ch/docs/r/r049.pdf EBU R 049]
Remark: Stereo
-
[http://www.digitalproductionpartnership.co.uk/downloads/standards/ BBC GLITS]
-
- Examples
-
-
00:10:39:00 - 00:10:41:00 2 seconds of 440 kHz tone detected on channel 1.
-
Input parameters
Name | Description |
---|
Output parameters
Name | Description |
---|
Test material
Title | Version | Download |
---|
Remarks
- Remarks
-
This test can be used to detect tones during programme material i.e. where they are not wanted.
It can also be used to detect the presence of test tones where the are required and to detect the type of tone. For example 1kHz tone is expected at 09:59:30:00 for 20 seconds
Golden Eyes/Ears EBU QC Test Item 0102B (AV LIneup) can be used where automation is not viable.
Note: that legacy material may have tone frequencies slightly different from the expected value, so the expected value is optional.
User discussions
Title | Author | Last update |
---|